TECHNICAL
KILOWATT HOURS TO HEAT OIL
Amount of Oil
Temperature Rise
Cubic
Ft.
Gallons
Litres
°F
50
100
200
300
400
500
°C
10
37.8
93
149
204
260
Kilowatts to heat in one hour
0.5
3.74
14.16
0.3
0.5
1
2
2
3
1
7.48
28.32
0.5
1
2
3
4
6
2
14.96
56.64
1
1
2
4
6
11
3
22.44
84.96
2
3
6
9
12
16
4
29.92
113.28
2
4
8
12
16
22
5
37.41
141.60
3
4
9
15
20
25
10
74.81
283.20
5
9
18
29
40
52
15
112.22
424.80
7
14
28
44
60
77
20
149.62
566.40
9
18
37
58
80
102
25
187.03
708.00
11
22
46
72
100
127
30
224.43
849.60
13
27
56
86
120
151
35
261.84
991.20
16
31
65
100
139
176
40
299.24
1132.80
18
36
74
115
158
201
45
336.65
1274.40
20
40
84
129
178
226
50
374.05
1416.00
22
45
93
144
197
252
55
411.46
1557.60
25
49
102
158
217
276
60
448.86
1699.20
27
54
112
172
236
302
65
486.27
1840.80
29
58
121
186
255
326
70
523.67
1982.40
32
62
130
200
275
350
75
561.08
2124.00
34
67
140
215
294
375

Add 5% for Uninsulated Tanks.

Equation to calculate kilowatts:

KW = Liters x Temperature Rise (°C)
             1680 x Heat-up Time (hrs.)

 

 

| KW hours heat Steel | KW hours heat Water | KW hours heat Air | KW hours heat Oil | Watt Density Chat |

| KW hours heat Steel | KW hours heat Water | KW hours heat Air | KW hours heat Oil | Watt Density Chat |

| KW hours heat Steel | KW hours heat Water | KW hours heat Air | KW hours heat Oil | Watt Density Chat |

| KW hours heat Steel | KW hours heat Water | KW hours heat Air | KW hours heat Oil | Watt Density Chat |

| Appliances | Water Heater | Component Heater | Immersion Heater | Circulation Heaters |
| Process Air Heaters | Canteen Equipments | Control Panel |

 

Site Best Viewed 800 x 600 Pixels IE -5 & above
Web Developers
SPRINT INFOTECH LTD.